REPLACEMENT CONTROL HONEYWELL IGNITION MODULE

Buy Replacement Control Honeywell Ignition Module

Honeywell S8610U3009 Universal Replacement Intermittent Pilot Module provides sequence, monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances and cane be used with natural or LP gas. It also supports EnviraCOM communications. The S8610U can replace more than 300 and competitive models. The S8610U has built-in safety by providing 100% pilot gas shutoff if the pilot fails to light. This model also has an LED strength indicator.

S8670 Intermittent Pilot Module provides electronic control of intermittent pilot systems used on gas-fired furnaces, boilers and other heating appliances. It also provides sequences, monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances.

S8910U1000 Universal Hot Surface Module gives operating control of a direct system using a 120VAC hot surface ignitor. This is usable on both single-rod and dual-rod hot surface systems. The S8910U1000 has LEDs to signal a system lockout, weak signal, or another internal error. Replaces more than 100 HSI modules, including Honeywell, White-Rodgers, and Robertshaw.

The S87D1004 Direct Spark Module from provide electronic control of direct spark systems used on gas fire furnaces, boilers and other heating appliances. being a large manufacturer of has very many models. Other models like S8600B,C,H,M; S8610B,C,H,M; S8670D,E,J,K are also standard products. The 8600 family ofprovide sequence, monitoring and safety shutoff for intermittent pilot gas fired heating appliances. Theseprovide sense and operating sequences suitable for the application. The 8600 family of provide sequence, monitoring and safety shutoff for intermittent pilot gas fired heating appliances. These provide sense and operating sequences suitable for the application.

The oil burner control the oil burner sequence of operation. When the thermostat is adjusted for heat, the oil burner control starts the burner blower. This is internally connected to the oil pump. The blower blows air into the combustion chamber and the oil pump pumps oil to the burners oil nozzle. A cad cell eye detects the and signals the oil burner control that everything is fine and the can continue burning. Until the thermostat is adjusted to stop the heat, the oil burner will continue to produce a .

We provide you the widest range of HVAC products for any of your replacement needs. All manufactured furnace and related products can be purchased at HVACPLUS.