1 2 3 4 5 6 7

Buy Replacement condenser coils

Contact Us: Phone: (800) 431-3137 or "Request Quote for Coil Product"

The replacement condenser coils are tubes that carry refrigerant so that it can be cooled easily. All replacement condenser coils applied on stainless steel units that are supplied with stainless steel casings. In addition to the coil casing, our various fin and tube combinations provide flexibility for wide fin spacing. This allows the coil surface to be cleaned more easily, minimizing dirt and dust that builds up inside the coil, and allows potentially corrosive particulate matter to fall through the coil instead of lying on the fin surface. Replacement condenser coils are usually used in Condenser, Desuper heater, and Reheat applications. The applications comprise of the replacement condenser coil which takes the superheated vapor from the compressor and cools that vapor down to saturation. It then completely condenses the entire vapor into liquid, and continues to sub cool the resulting liquid to a desired temperature below saturation. The process proceeds applying reheating coil. This is a hot gas reheat coil which takes the superheated vapor from the compressor and cools the vapor down to saturation. It then continues to condense a requested percentage of that vapor to a liquid. Then comes the desuper heater coil which takes the superheated vapor from the compressor and cools that vapor down to a requested temperature above saturation. The replacement condenser coil is constructed using the tubing with specifications ranging from 3/8" or 1/2" O.D. Copper, 5/8" O.D. Copper, Stainless Steel, or Carbon Steel. The circuiting used may be Standard one section or multiple sections. The rows may vary from 1, 2, 3, 4, 5, 6, 8, 10; 12.The fin surface may be Sine Wave (corrugated), New Ripple (peak and valley) or Flat. The casing used can be Galvanized Steel, Stainless Steel, Carbon Steel, Copper or Aluminum .Further, the connections maybe Copper Sweat, Carbon Steel or Stainless Steel. High-efficiency air-conditioning units incorporate a number of features to reduce electricity consumption. These mainly comprise of Replacement condenser coiled condensers. The condenser may be made larger to reduce the condensing temperature and compression ratio. Condenser fans which are propeller fans are sized and shaped for efficient operation at full and part load. Filters and cooling coil are larger to reduce the airflow velocity and improve heat transfer. They are also designed to have easy access for cleaning. Replacement condenser coils can be cleaned with a replacement condenser coil cleaner which has high foaming action that carries dirt, grease, etc. out from center of coils .It leaves coil fins cleaner and brighter. The replacement of the condenser coil is likely at the supplier of the HVAC Plus Products. The supplier supplies the original coil condenser and manufacturer gives the assurance of its products. All the products are easily available so that there should not be any type of hassles in the work. The dealer gives the services with assertion and all repair parts can be easily replaced.

 

Replacement condenser coils are used in the repair of heat pump and air conditioning systems. They are also found in desuperheaters and reheat systems. The coil is constructed using copper tubing through which refrigerant flows. The tubing is welding to large plates that feature fins on the exterior side, very much like a car radiator or the back of a window AC unit. When in AC mode, the system returns refrigerant from the coil installed in the air handler. The refrigerant returns as a hot gas carrying heat from the home or building. Inside the condenser coil, it is converted by into a liquid, and it sheds the heat. The heat radiates out through the plates and fins.

Coils need to be cleaned on a regular basis to prevent the buildup of debris on their surface. Dirt and debris can be corrosive to the coil. They can also prevent the easy transfer of heat through the surface. The system will have to work harder to heat or cool, and the results will be higher utility bills and more mechanical failures. Cleaning should be done only with cleaners approved for the type of surface the condenser has.

In reheat applications, the refrigerant vapor is cooled in order to return it to a liquid state at a temperature below saturation. A hot gas reheat coil cools the superheated refrigerant vapor until the correct percentages of vapor and liquid are reached. The desuperheater coil further reduces the temperature of the refrigerant before it is recycled into the air handler to collect more heat.

Tubing used in replacement condenser coils has on outside diameter (O.D) ranging from 3/8" to 1/2" if made from copper. Tubing with an O.D. of 5/8" is also made with copper, carbon steel or stainless steel. Single-section and multiple-section circuiting is used in various configurations. Rows from 1 to 12 are common in replacement condenser coils. There are many different fin configurations too. The condenser coil works in conjunction with a fan to dissipate heat released by the hot refrigerant. Fans are sized to meet the cooling demands of the condenser.

HVAC Plus has the largest inventory of replacement condenser coils you'll find online or from local suppliers. When you buy replacement condenser coils from HVAC Plus, we'll complete your order quickly and get it out the door on the next truck headed your way.